3.2 Typical Hardware Connections
The INA219EVM hardware setup involves connecting the two PCBs of the EVM together, applying power,
and connecting an external shunt and load. The external connections may be the real-world system that
the INA219 will be incorporated into. Figure 6 shows the typical hardware connections.
Figure 6. Typical Hardware Connections
3.3 Connecting the Hardware
To connect the two PCBs of the INA219EVM together, gently push on both sides of the D-SUB connectors
(as shown in Figure 7). Make sure that the two connectors are completely pushed together; loose
connections may cause intermittent operation.
8
INA219 Evaluation Module SBOU074A–January 2009–Revised February 2010
Submit Documentation Feedback
Copyright © 2009–2010, Texas Instruments Incorporated