Datasheet
Max_Current=Current_LSB 32767´
Max_Current=0.06226
Max_ShuntVoltage=Max_Current_Before_Overflow R´
SHUNT
Max_ShuntVoltage=0.3113
MaximumPower=Max_Current_Before_Overflow V´
BUS_MAX
MaximumPower=1.992
Corrected_Full_Scale_Cal=trunc
Cal MeasShuntCurrent
INA219_Current
´
Corrected_Full_Scale_Cal=3462
INA219
www.ti.com
SBOS448F –AUGUST 2008– REVISED SEPTEMBER 2011
7. Compute the maximum current and shunt voltage values (before overflow), as shown by Equation 15 and
Equation 16. Note that both Equation 15 and Equation 16 involve an If - then condition.
(15)
If Max_Current ≥ Max Possible_I then
Max_Current_Before_Overflow = MaxPossible_I
Else
Max_Current_Before_Overflow = Max_Current
End If
(Note that Max_Current is less than MaxPossible_I in this example.)
Max_Current_Before_Overflow = 0.06226 (Note: This result is displayed by software as seen in Figure 22.)
(16)
If Max_ShuntVoltage ≥ V
SHUNT_MAX
Max_ShuntVoltage_Before_Overflow = V
SHUNT_MAX
Else
Max_ShuntVoltage_Before_Overflow= Max_ShuntVoltage
End If
(Note that Max_ShuntVoltage is less than V
SHUNT_MAX
in this example.)
Max_ShuntVoltage_Before_Overflow = 0.3113 (Note: This result is displayed by software as seen in
Figure 22.)
8. Compute the maximum power with equation 8.
(17)
9. (Optional second calibration step.) Compute the corrected full-scale calibration value based on measured
current.
INA219_Current = 0.06226
MeaShuntCurrent = 0.05
(18)
Copyright © 2008–2011, Texas Instruments Incorporated Submit Documentation Feedback 21
Product Folder Link(s): INA219