Datasheet

Power Measurement
Peak-Hold Registers
INA209
SBOS403B JUNE 2007 REVISED MARCH 2009 .........................................................................................................................................................
www.ti.com
When the INA209 is in the normal operating mode The Conversion Ready bit clears under these
(that is, MODE bits of the Configuration Register are conditions:
set to '111'), it continuously converts the shunt
1. Writing to the Configuration Register, except
voltage up to the number set in the shunt voltage
when configuring the MODE bits for Power Down
averaging function (Configuration Register, SADC
or ADC off (Disable) modes;
bits). The device then converts the bus voltage up to
2. Reading the Status Register; or
the number set in the bus voltage averaging
3. Triggering a single-shot conversion with the
(Configuration Register, BADC bits). The Mode
Convert pin.
control in the Configuration Register also permits
selecting modes to convert only voltage or current,
either continuously or in response to an event
(triggered).
Current and bus voltage are converted at different
points in time, depending on the resolution and
All current and power calculations are performed in
averaging mode settings. For instance, when
the background and do not contribute to conversion
configured for 12-bit and 128 sample averaging, up to
time; conversion times shown in the Electrical
68ms in time between sampling these two values is
Characteristics table can be used to determine the
possible. Again, these calculations are performed in
actual conversion time.
the background and do not add to the overall
Power-Down mode reduces the quiescent current
conversion time.
and turns off current into the INA209 inputs, avoiding
any supply drain. Full recovery from Power-Down
requires 40 µ s. ADC Off mode (set by the
Configuration Register, MODE bits) stops all Shunt voltage peak registers hold the lowest and
conversions. highest converted reading for the shunt value. The
shunt value may be either positive or negative; as a
In triggered mode, the external Convert line becomes
result, there is a need for a sign bit in either register.
active. Convert commands are initiated by taking the
For instance, the Shunt Voltage Positive Peak
Convert line low for a minimum of 4 µ s. The Convert
Register in most systems records a positive voltage;
line may be connected high when unused. Any
in most unidirectional current measurement
re-trigger of the Convert line during a conversion is
applications, the Shunt Voltage Negative Peak
ignored, and the Convert line state is disregarded
Register also records a positive voltage. However,
until the conversion ends. There are several available
certain conditions can occur in normally unidirectional
triggered modes; however, all conversions are
systems that cause a negative polarity across the
performed repeatedly up to the number set in the
shunt; these events are recorded in the Shunt
Averaging function (Configuration Register, BADC
Voltage Negative Peak Register.
and SADC bits).
Peak-hold registers do not record conditions that
If the Convert line is held low, writing any of the
trigger a Critical Comparator shutdown. A Critical
triggered convert modes into the Configuration
Comparator shutdown occurs within 5 µ s of detecting
Register (even if the desired mode is already
a critical condition, while the ADC conversion
programmed into the register) triggers a single-shot
necessary to record a peak-hold requires 532 µ s.
conversion.
Therefore, a system shutdown removes the fault
before the analog-to-digital conversion (ADC) can
Although the INA209 can be read at any time, and
record it.
the data from the last conversion remain available,
the Conversion Ready bit (Status Register, CNVR bit)
is provided to help co-ordinate one-shot or triggered
conversions. The Conversion Ready bit is set after all
conversions, averaging, and multiplication operations
are complete.
16 Submit Documentation Feedback Copyright © 2007 2009, Texas Instruments Incorporated
Product Folder Link(s): INA209