Datasheet

1
2
3
4
5
V+
V
IN–
V
IN+
GND
OUT
INA193A
INA194A
INA195A
DBV PACKAGE
(TOP VIEW)
1
2
3
4
5
V
IN–
V
IN+
V+
GND
OUT
INA196A
INA197A
INA198A
DBV PACKAGE
(TOP VIEW)
ABSOLUTE MAXIMUM RATINGS
(1)
INA193A-Q1 , INA194A-Q1 , INA195A-Q1
INA196A-Q1 , INA197A-Q1 , INA198A-Q1
SBOS366C AUGUST 2006 REVISED OCTOBER 2008 ...............................................................................................................................................
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
ORDERING INFORMATION
(1)
T
A
PACKAGE
(2)
ORDERABLE PART NUMBER TOP-SIDE MARKING
INA193AQDBVRQ1 BOG
INA194AQDBVRQ1 BOH
INA195AQDBVRQ1 BOI
40 ° C to 125 ° C SOT-23 DBV Reel of 3000
INA196AQDBVRQ1 BOJ
INA197AQDBVRQ1 BOK
INA198AQDBVRQ1 BOL
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the
website at www.ti.com.
(2) Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at
www.ti.com/sc/package.
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
Supply voltage 18 V
Differential input voltage range, analog inputs (V
IN+
V
IN
) 18 18 V
Common-mode voltage range
(2)
16 80 V
Analog output voltage range
(2)
OUT GND 0.3 (V+) + 0.3 V
Input current into any pin
(2)
5 mA
Storage temperature range 65 150 ° C
Junction temperature 150 ° C
Human-Body Model 4000
ESD qualification ratings Machine Model 200 V
Charged-Device Model 1000
(1) Stresses beyond those listed under " absolute maximum ratings " may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under " recommended operating
conditions " is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Input voltage at any pin may exceed the voltage shown if the current at that pin is limited to 5 mA.
2 Submit Documentation Feedback Copyright © 2006 2008, Texas Instruments Incorporated
Product Folder Link(s): INA193A-Q1 INA194A-Q1 INA195A-Q1 INA196A-Q1 INA197A-Q1 INA198A-Q1