User Manual

September 2001 S6350 Reader Reference Guide
11
2.1.6 Baseband receiver
Minimum data pulse width 5uS
Maximum data pulse width 500uS
Typical settling time 50uS from the first transition
Note:
The receiver extracts the mean level of the incoming data stream as
a reference. This takes approximately 50uS; therefore the data
output of the receiver is not valid until after this time.
2.1.7 Connector Details
All reader input and output is provided through a 16-pin header connector that is mounted on the
backside of the reader for the RI-STU-TRDC-02 and on the component side for the RI-STU-
TRDC-01. The details and orientation of each connector pin are provided in the following tables.
2.1.8 16-pin Header Connector CN1
Pin Function
1 0 Volts
2 +5 Volts
3 Open collector output / data input 2
4 Open collector output / data input 1
5 RS232 TxD (output from reader)
6 RS232 RxD (input to reader)
7 No connection (antenna guard)
8 Antenna screen
9 Antenna signal
10 No connection (antenna guard)
11 RS232 ground
12 No connection (reserved for future expansion)
13 No connection (reserved for future expansion)
14 No connection (reserved for future expansion)
15 No connection (reserved for future expansion)
16 No connection (reserved for future expansion)
CAUTION:
Only pins 8 and 9 of connector CN1 should be used for
the antenna connection.