5.22 Receive Unicast Clear Register (RXUNICASTCLEAR)
Ethernet Media Access Controller (EMAC) Registers
The receive unicast clear register (RXUNICASTCLEAR) is shown in Figure 48 and described in
Table 47 .
Figure 48. Receive Unicast Clear Register (RXUNICASTCLEAR)
31 16
Reserved
R-0
15 8
Reserved
R-0
7 6 5 4 3 2 1 0
RXCH7EN RXCH6EN RXCH5EN RXCH4EN RXCH3EN RXCH2EN RXCH1EN RXCH0EN
R/WC-0 R/WC-0 R/WC-0 R/WC-0 R/WC-0 R/WC-0 R/WC-0 R/WC-0
LEGEND: R = Read only; R/W = Read/Write; WC = Write 1 to clear, write of 0 has no effect; - n = value after reset
Table 47. Receive Unicast Clear Register (RXUNICASTCLEAR) Field Descriptions
Bit Field Value Description
31-8 Reserved 0 Reserved
7 RXCH7EN 0-1 Receive channel 7 unicast enable clear bit. Write 1 to clear the enable, a write of 0 has no effect.
6 RXCH6EN 0-1 Receive channel 6 unicast enable clear bit. Write 1 to clear the enable, a write of 0 has no effect.
5 RXCH5EN 0-1 Receive channel 5 unicast enable clear bit. Write 1 to clear the enable, a write of 0 has no effect.
4 RXCH4EN 0-1 Receive channel 4 unicast enable clear bit. Write 1 to clear the enable, a write of 0 has no effect.
3 RXCH3EN 0-1 Receive channel 3 unicast enable clear bit. Write 1 to clear the enable, a write of 0 has no effect.
2 RXCH2EN 0-1 Receive channel 2 unicast enable clear bit. Write 1 to clear the enable, a write of 0 has no effect.
1 RXCH1EN 0-1 Receive channel 1 unicast enable clear bit. Write 1 to clear the enable, a write of 0 has no effect.
0 RXCH0EN 0-1 Receive channel 0 unicast enable clear bit. Write 1 to clear the enable, a write of 0 has no effect.