Datasheet
Table 30-28. Wake from Deep Sleep Characteristics (continued)
UnitMaxNomMinParameter NameParameterParameter
No
µs15--Time to restore SRAM to active state from
standby state
T
SRAMSTBYDS
D14
a. Deep Sleep Clock can vary. See page 288 for the Deep Sleep Clock options.
June 18, 20141968
Texas Instruments-Production Data
Electrical Characteristics