Datasheet
■ Can initiate an ADC sample sequence
The control block determines the polarity of the PWM signals and which signals are passed through
to the pins. The output of the PWM generation blocks are managed by the output control block
before being passed to the device pins. The PWM control block has the following options:
■ PWM output enable of each PWM signal
■ Optional output inversion of each PWM signal (polarity control)
■ Optional fault handling for each PWM signal
■ Synchronization of timers in the PWM generator blocks
■ Synchronization of timer/comparator updates across the PWM generator blocks
■ Extended PWM synchronization of timer/comparator updates across the PWM generator blocks
■ Interrupt status summary of the PWM generator blocks
■ Extended PWM fault handling, with multiple fault signals, programmable polarities, and filtering
■ PWM generators can be operated independently or synchronized with other generators
26.1 Block Diagram
Figure 26-1 on page 1795 provides the TM4C129ENCPDT PWM module diagram and Figure
26-2 on page 1795 provides a more detailed diagram of a TM4C129ENCPDT PWM generator. The
TM4C129ENCPDT controller contains four generator blocks that generate eight independent PWM
signals or four paired PWM signals with dead-band delays inserted.
June 18, 20141794
Texas Instruments-Production Data
Pulse Width Modulator (PWM)