Datasheet

DescriptionResetTypeNameBit/Field
MII Link Status
DescriptionValue
No active link of 100BT full-duplex has been established using
Auto-Negotiation.
0
100BT Full-duplex Link is active and was established using
Auto-Negotiation.
1
0ROMIILNKSTAT11
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0ROreserved10:8
Bypass LED Stretching
This bypasses LED stretching and allows the LEDs to reflect normal
operation values.
DescriptionValue
Normal LED operation.0
Bypass LED stretching.1
0RWBYPLEDSTRCH7
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0ROreserved6:0
1759June 18, 2014
Texas Instruments-Production Data
Tiva
TM4C129ENCPDT Microcontroller