Datasheet

Setup Procedure
1. Configure DVEN, TM1, TM2, and number-of-cells
(NOC) jumpers.
2. Connect the provided thermistor or a 10K
resistor
between THERM and BAT–.
Note: RT1 and RT2 match the thermistor provided
and must be changed if a different thermistor type
is used (see Appendix A in the application note,
“Using the bq2003 to Control Fast Charge”).
3. If using the discharge-before-charge option, connect
a current-limiting discharge load between BAT+
and DSCHG.
4. If using the INHIBIT function, connect a switch
across JP5 (IN to +V) or connect IN to the control
-
ling signal source (3–5V).
5. Attach the battery pack to BAT+ and BAT–. For
temperature control, the thermistor must contact
the cells.
6. Attach DC current source to DC+ (+) and GND (–)
connections in JP6.
3
DV2003S2
Symbol Description Minimum Typical Maximum Unit Notes
I
DC+
Maximum input current - - 6.0 A
V
DC+
Maximum input voltage
2.0+V
BAT+
or 8.0
-
30
V
V
BAT+
BAT+ input voltage - - 30 V
V
THERM
THERM input voltage 0 - 5 V
V
IN
Inhibit input signal 0 - 5 V
I
DSCHG
Discharge load current - - 2 A
Recommended DC Operating Conditions
Closed Jumper Number of Cells
R25 16
R24 14
R23 12
R22 10
R21 8
R20 6
R19 5
R18 4
R17 3
R16 2