Datasheet

DS92LX1621, DS92LX1622
www.ti.com
SNLS327I MAY 2010REVISED JANUARY 2014
INTERCONNECT GUIDELINES
For full details, see the Channel-Link PCB and Interconnect Design-In Guidelines (literature number SNLA008)
and the Transmission Line RAPIDESIGNER Operation and Applications Guide (literature number SNLA035).
Use 100 coupled differential pairs
Use the S/2S/3S rule in spacings
S = space between the pair
2S = space between pairs
3S = space to LVCMOS signal
Minimize the number of Vias
Use differential connectors when operating above 500Mbps line speed
Maintain balance of the traces
Minimize skew within the pair
Additional general guidance can be found in the LVDS Owner’s Manual (literature number SNLA187), which is
available in PDF format from the TI LVDS & CML Solutions web site.
Copyright © 2010–2014, Texas Instruments Incorporated Submit Documentation Feedback 39