Datasheet

DS92LV2421, DS92LV2422
SNLS321B MAY 2010REVISED APRIL 2013
www.ti.com
LVDS INTERCONNECT GUIDELINES
See AN-1108(SNLA008) and AN-905(SNLA035) for full details.
Use 100Ω coupled differential pairs
Use the S/2S/3S rule in spacings
S = space between the pair
2S = space between pairs
3S = space to LVCMOS signal
Minimize the number of Vias
Use differential connectors when operating above 500Mbps line speed
Maintain balance of the traces
Minimize skew within the pair
Terminate as close to the TX outputs and RX inputs as possible
Additional general guidance can be found in the LVDS Owner’s Manual - available in PDF format from the Texas
Instruments web site at: http://www.ti.com/ww/en/analog/interface/lvds.shtml
42 Submit Documentation Feedback Copyright © 2010–2013, Texas Instruments Incorporated
Product Folder Links: DS92LV2421 DS92LV2422