Datasheet

DS90UR905Q, DS90UR906Q
www.ti.com
SNLS313G SEPTEMBER 2009REVISED APRIL 2013
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
Absolute Maximum Ratings
(1)(2)(3)
Supply Voltage – V
DDn
(1.8V) 0.3V to +2.5V
Supply Voltage – V
DDIO
0.3V to +4.0V
LVCMOS I/O Voltage 0.3V to +(VDDIO + 0.3V)
Receiver Input Voltage 0.3V to (VDD + 0.3V)
Driver Output Voltage 0.3V to (VDD + 0.3V)
Junction Temperature +150°C
Storage Temperature 65°C to +150°C
Maximum Power Dissipation Capacity at 25°C 215mW
Derate above 25°C 1/θ
JA
mW / °C
48L RHS Package
θ
JA
(based on 9 thermal vias) 27.1 °C/W
θ
JC
(based on 9 thermal vias) 4.5 °C/W
Maximum Power Dissipation Capacity at 25°C 470mW
Derate above 25C 1/θ
JA
mW / °C
60L NKB Package
θ
JA
(based on 9 thermal vias) 24.6 °C/W
θ
JC
(based on 9 thermal vias) 2.8 °C/W
ESD Rating (HBM) ±8 kV
ESD Rating (CDM) ±1 kV
ESD Rating (MM) ±250 V
Air Discharge (D
OUT+
, D
OUT
) ±30 kV
ESD Rating (ISO10605), R
D
= 2kΩ, C
S
=
Contact Discharge (D
OUT+
, D
OUT
) ±10 kV
150pF or R
D
= 2kΩ, C
S
= 330pF or R
D
= 330Ω,
Air Discharge (R
IN+
, R
IN
) ±30 kV
C
S
= 150pF
Contact Discharge (R
IN+
, R
IN
) ±10 kV
Air Discharge (D
OUT+
, D
OUT
) ±15 kV
Contact Discharge (D
OUT+
, D
OUT
) ±10 kV
ESD Rating (ISO10605), R
D
= 330Ω, C
S
=
330pF
Air Discharge (R
IN+
, R
IN
) ±15 kV
Contact Discharge (R
IN+
, R
IN
) ±10 kV
Air Discharge (D
OUT+
, D
OUT
) ±25 kV
Contact Discharge (D
OUT+
, D
OUT
) ±8 kV
ESD Rating (IEC 61000-4-2), R
D
= 330Ω, C
S
=
150pF
Air Discharge (R
IN+
, R
IN
) ±25 kV
Contact Discharge (R
IN+
, R
IN
) ±8 kV
(1) “Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur, including inoperability and degradation of
device reliability and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or
other conditions beyond those indicated in the Recommended Operating Conditions is not implied. The Recommended Operating
Conditions indicate conditions at which the device is functional and the device should not be operated beyond such conditions.
(2) If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/ Distributors for availability and
specifications.
(3) For soldering specifications see product folder at www.ti.com and http://www.ti.com/lit/an/snoa549c/snoa549c.pdf
Copyright © 2009–2013, Texas Instruments Incorporated Submit Documentation Feedback 11
Product Folder Links: DS90UR905Q DS90UR906Q