Datasheet

DS90CP22
SNLS053E MARCH 2000REVISED APRIL 2013
www.ti.com
AC Electrical Characteristics (continued)
Over recommended operating supply and temperature ranges unless otherwise specified
(1)
Symbol Parameter Conditions Min Typ Max Units
T
JIT
V
ID
= 300mV; 50% Duty Cycle; V
CM
=
40 90 ps
1.2V at 800Mbps
LVDS Data Path Peak to Peak Jitter
(3)
V
ID
= 300mV; PRBS=2
23
-1 data
65 120 ps
pattern; V
CM
= 1.2V at 800Mbps
T
PLHD
Propagation Low to High Delay, Figure 8 0.9 1.3 1.6 ns
Propagation Low to High Delay, Figure 8 V
CC
= 3.3V, T
A
= 25°C 1.0 1.3 1.5 ns
T
PHLD
Propagation High to Low Delay, Figure 8 0.9 1.3 1.6 ns
Propagation High to Low Delay, Figure 8 V
CC
= 3.3V, T
A
= 25°C 1.0 1.3 1.5 ns
T
SKEW
Pulse Skew |T
PLHD
- T
PHLD
| 0 225 ps
T
CCS
Output Channel-to-Channel Skew, Figure 9 35 80 ps
(3) The parameters are specified by design. The limits are based on statistical analysis of the device performance over PVT range with the
following equipment test setup: HP70004A (display mainframe) with HP70841B (pattern generator), 5 feet of RG-142 cable with DUT
test board and HP83480A (digital scope mainframe) with HP83483A (20GHz scope module).
AC Timing Diagrams
Figure 3. Input-to-Select rising edge setup and hold times and mux switch time
Figure 4. Input-to-Select falling edge setup and hold times and mux switch time
4 Submit Documentation Feedback Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: DS90CP22