Over recommended operating supply and temperature ranges unless otherwise specified.
Symbol Parameter Conditions Min Typ Max Unit
f
SC
S2CLK Clock Frequency 400 kHz
SC:LOW Clock Low Period R
P
= 4.7K, C
L
= 50pF 1.5 us
SC:HIGH Clock High Period R
P
= 4.7K, C
L
= 50pF 0.6 us
SCD:TR S2CLK and S2DAT Rise Time R
P
= 4.7K, C
L
= 50pF 0.3 us
SCD:TF S2CLK and S2DAT Fall Time R
P
= 4.7K, C
L
= 50pF 0.3 us
SU:STA Start Condition Setup Time R
P
= 4.7K, C
L
= 50pF 0.6 us
HD:STA Start Condition Hold Time R
P
= 4.7K, C
L
= 50pF 0.6 us
HD:STO Stop Condition Hold Time R
P
= 4.7K, C
L
= 50pF 0.6 us
SC:SD Clock Falling Edge to Data R
P
= 4.7K, C
L
= 50pF 0 us
SD:SC Data to Clock Rising Edge R
P
= 4.7K, C
L
= 50pF 0.1 us
SCL:SD S2CLK Low to S2DAT Data Valid R
P
= 4.7K, C
L
= 50pF 0.1 0.9 us
BUF Bus Free Time R
P
= 4.7K, C
L
= 50pF 13 us
Copyright © 2005–2013, Texas Instruments Incorporated Submit Documentation Feedback 7