Datasheet

(1)
(2)
(1)
(2)
DS36954
SNLS077C JULY 1998REVISED APRIL 2013
www.ti.com
S1 to OA for DI = 3V
S1 to OB for DI = 0V
(1) The input pulse is supplied by a generator having the following characteristics: f = 1.0 MHz, 50% duty cycle, trand tf <
6.0 ns, ZO = 50Ω.
(2) C
L
includes probe and stray capacitance.
Figure 5.
Figure 6. Driver Enable and Disable Timing (t
PZH
, t
PHZ
)
S1 to OA for DI = 0V
S1 to OB for DI = 3V
(1) The input pulse is supplied by a generator having the following characteristics: f = 1.0 MHz, 50% duty cycle, trand tf <
6.0 ns, ZO = 50Ω.
(2) C
L
includes probe and stray capacitance.
Figure 7.
6 Submit Documentation Feedback Copyright © 1998–2013, Texas Instruments Incorporated