Datasheet
Absolute Maximum Ratings (Note 1)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Supply Voltage 7.0V
Input Voltage 15V
Output Voltage 70V
Continuous Power Dissipation
@
25˚C Free-Air (Note 5) 2075 mW
Storage Temperature Range −65˚C to +150˚C
Lead Temperature
(Soldering, 4 seconds) 260
Operating Conditions
Min Max Units
Supply Voltage 3.00 5.25 V
Ambient Temperature −40 125 ˚C
Electrical Characteristics (Notes 2, 3, 6)
Symbol Parameter Conditions Min Typ Max Units
V
IH
Input High Voltage 2.0 V
V
IL
Input Low Voltage 0.8 V
I
IH
Input High Current V
IN
= 5.25V, V
CC
= 5.25V 1.0 20 µA
I
IL
Input Low Current V
IN
= 0.4V
±
10 µA
V
IK
Input Clamp Voltage I
I
= −12 mA −0.8 −1.5 V
V
OL
Output Low Voltage I
L
= 300 mA 0.2 0.7 V
I
L
= 600 mA (Note 4) 0.55 1.5 V
I
CEX
Output Leakage Current V
CE
= 70V, V
IN
= 0.8V 100 µA
V
F
Diode Forward Voltage I
F
= 800 mA 1.2 1.6 V
I
R
Diode Leakage Current V
R
= 70V 100 µA
I
CC
Supply Current All Inputs High 62 80 mA
All Inputs Low 20 mA
I
TH
Protection Circuit
Threshold Current
1 1.4 A
Switching Characteristics (Notes 2, 6)
Symbol Parameter Conditions Min Typ Max Units
t
PHL
Turn On Delay R
L
=60Ω,V
L
= 30V 0.3 1.0 µs
t
PLH
Turn Off Delay R
L
=60Ω,V
L
= 30V 2 10.0 µs
t
FZ
Protection Enable Delay
(after Detection of Fault)
612 µs
t
RL
Input Low Time for
Protection Circuit Reset
1.0 µs
Note 1: “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. They are not meant to imply that the devices
should be operated at these limits. The table of “Electrical Characteristics” specifies conditions of actual device operation.
Note 2: Unless otherwise specified, min/max limits apply across the 0˚C to +70˚C temperature range and the 4.75V to 5.25V power supply range. All typical values
are for T
A
= 25˚C and V
CC
= 5.0V.
Note 3: All currents into device pins are shown as positive; all currents out of device pins are shown as negative; all voltages are referenced to ground, unless
otherwise specified. All values shown as max or min are so classified on absolute value basis.
Note 4: All sectors of this quad circuit may conduct rated current simultaneously, however, power dissipation averaged over a short interval of time must fall within
specified continuous dissipation ratings.
Note 5: For operation over 25˚C free-air temperature, derate linearly to 1328 mW
@
70˚C
@
the rate of 16.6 mW/˚C.
Note 6: Datasheet min/max specification limits are guaranteed by design, test, or statistical analysis.
DS3668
www.national.com3