Datasheet

DS25CP102
www.ti.com
SNLS262E OCTOBER 2007REVISED MARCH 2013
PIN DESCRIPTIONS
Pin Name Pin I/O, Type Pin Description
Number
IN0+, IN0- , 1, 2, I, LVDS Inverting and non-inverting high speed LVDS input pins.
IN1+, IN1- 3, 4
OUT0+, OUT0-, 12, 11, O, LVDS Inverting and non-inverting high speed LVDS output pins.
OUT1+, OUT1- 10, 9
SEL0, SEL1 7, 8 I, LVCMOS Switch configuration pins. There is a 20k pulldown resistor on this pin.
EN0, EN1 14, 13 I, LVCMOS Output enable pins. There is a 20k pulldown resistor on this pin.
PE 15 I, LVCMOS Transmit Pre-Emphasis select pin. There is a 20k pulldown resistor on this pin.
EQ 6 I, LVCMOS Receive Equalization select pin. There is a 20k pulldown resistor on this pin.
VDD 16 Power Power supply pin.
GND 5, DAP Power Ground pin and Device Attach Pad (DAP) ground.
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
Absolute Maximum Ratings
(1)(2)
Supply Voltage 0.3V to +4V
LVCMOS Input Voltage 0.3V to (V
CC
+ 0.3V)
LVDS Input Voltage 0.3V to +4V
Differential Input Voltage |VID| 1.0V
LVDS Output Voltage 0.3V to (V
CC
+ 0.3V)
LVDS Differential Output Voltage 0V to 1.0V
LVDS Output Short Circuit Current Duration 5 ms
Junction Temperature +150°C
Storage Temperature Range 65°C to +150°C
Lead Temperature Range
Soldering (4 sec.) +260°C
Maximum Package Power Dissipation at 25°C
RGH0016A Package 2.99W
Derate RGH0016A Package 23.9 mW/°C above +25°C
Package Thermal Resistance
θ
JA
+41.8°C/W
θ
JC
+6.9°C/W
ESD Susceptibility
HBM
(3)
8 kV
MM
(4)
250V
CDM
(5)
1250V
(1) “Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur, including inoperability and degradation of
device reliability and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or
other conditions beyond those indicated in the Recommended Operating Conditions is not implied. The Recommended Operating
Conditions indicate conditions at which the device is functional and the device should not be operated beyond such conditions.
(2) If Military/Aerospace specified devices are required, please contact the TI Sales Office/Distributors for availability and specifications.
(3) Human Body Model, applicable std. JESD22-A114C
(4) Machine Model, applicable std. JESD22-A115-A
(5) Field Induced Charge Device Model, applicable std. JESD22-C101-C
Copyright © 2007–2013, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Links: DS25CP102