Electrical Characteristics (continued)
Parameter Test Conditions Min Typ Max Units
HIGH SPEED TRANSMITTER OUTPUTS
V
OD1
Output Voltage Differential Swing OUT+ and OUT- AC coupled and 425 575 725 mVp-p
terminated by 50Ω to GND
VOD_SEL = LOW
DE = LOW
V
OD2
Output Voltage Differential Swing OUT+ and OUT- AC coupled and 675 850 1025
terminated by 50Ω to GND
VOD_SEL = FLOAT
DE = LOW
V
OD3
Output Voltage Differential Swing OUT+ and OUT- AC coupled and 850 1050 1275
terminated by 50Ω to GND
VOD_SEL = 20K
DE = LOW
V
OD_DE1
De-Emphasis Levels OUT+ and OUT- AC coupled and - 3.5 dB
terminated by 50Ω to GND
VOD_SEL = FLOAT
DE = FLOAT
V
OD_DE2
De-Emphasis Levels OUT+ and OUT- AC coupled and - 6.0 dB
terminated by 50Ω to GND
VOD_SEL = FLOAT
DE = 20K
V
OD_DE3
De-Emphasis Levels OUT+ and OUT- AC coupled and - 9.0 dB
terminated by 50Ω to GND
VOD_SEL = FLOAT
DE = HIGH
V
CM-AC
Output Common-Mode Voltage AC Common Mode Voltage 4.5 mV
DE = 0 dB (RMS)
V
CM-DC
Output DC Common-Mode DC Common Mode Voltage 0 1.1 1.9 V
Voltage
V
IDLE
TX IDLE Output Voltage 30 mV
RL
TX-DIFF
TX return loss SDD22 @ 4.1 GHz -13 dB
SDD22 @ 11.1 GHz -9
SCC22 @ 2.5 GHz -22
SCC22 @ 11.1 GHz -10
delta Z
M
Transmitter Termination DC, I
FORCE
= +/- 100 uA
(4)
2.5 %
Mismatch
T
R/F
Transmitter Rise and Fall Time Measurement points at 20% - 80%
(5)
38 ps
T
PD
Propagation Delay Measured at 50% crossing 230 ps
EQ = 00
T
CCSK
Inter-pair Channel Skew T = 25°C, VDD = 2.5V 7 ps
T
PPSK
Part to Part Channel Skew T = 25°C, VDD = 2.5V 20 ps
T
TX-IDLE-SET-TO-IDLE
Max time to transition to idle VIN = 1Vpp, 10 Gbps 6.5 ns
after differential signal EQ = 00, DE = 0
T
TX-IDLE-TO-DIFF-DATA
Max time to transition to valid VIN = 1Vpp, 10 Gbps 3.2 ns
differential signal after idle EQ = 00, DE = 0
T
ENVELOPE_DISTORT
Active OOB timing distortion, 3.3 ns
input active time vs. output active
time
(4) Force +/- 100 uA on output, measure delta V on the Output and calculate impedance. Mismatch is the percentage difference of OUTn+
and OUTn- impedance driving the same logic state.
(5) Default VOD used for testing. DE = -1.5 dB level used to compensate for fixture attenuation.
Copyright © 2012–2013, Texas Instruments Incorporated Submit Documentation Feedback 7