Datasheet
STEP
DIR, USMx
SLEEPn, ENABLEn, RESETn
1
2
3
4
5
6
OUTPUT
8
10
7
9
11
DRV8811
www.ti.com
SLVS865H –SEPTEMBER 2008–REVISED NOVEMBER 2013
TIMING REQUIREMENTS
over operating free-air temperature range (unless otherwise noted)
PARAMETER MIN MAX UNIT
1 f
STEP
Step frequency 500 kHz
2 t
WH(STEP)
Pulse duration, STEP high 1 μs
3 t
WL(STEP)
Pulse duration, STEP low 1 μs
4 t
SU(STEP)
Setup time, command before STEP rising 200 ns
5 t
H(STEP)
Hold time, command after STEP rising 200 ns
6 t
WAKE
Wakeup time, SLEEPn inactive high to STEP input accepted 1 ms
7 t
SLEEP
Sleep time, SLEEPn active low to outputs disabled 5 μs
8 t
ENABLE
Enable time, ENABLEn inactive high to outputs enabled 20 μs
9 t
DISABLE
Disable time, ENABLEn active low to outputs disabled 20 μs
10 t
RESETR
Reset release time, RESETn inactive high to outputs enabled 5 μs
11 t
RESET
Reset time, RESETn active low to outputs disabled 5 μs
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 7
Product Folder Links: DRV8811