Datasheet

DRV603
SLOS617C JANUARY 2009REVISED NOVEMBER 2009
www.ti.com
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
ORDERING INFORMATION
(1)
T
A
PACKAGE TRANSPORT MEDIA, QUANTITY
DRV603PW RAIL, 90
–40°C to 85°C
Tape and reel, 2000
DRV603PWR
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
Web site at www.ti.com.
ABSOLUTE MAXIMUM RATINGS
(1)
over operating free-air temperature range
VALUE UNIT
Supply voltage, V
DD
to GND –0.3 to 5.5 V
V
I
Input voltage V
SS
– 0.3 to V
DD
+ 0.3 V
R
L
Minimum load impedance > 600
EN to GND –0.3 to V
DD
+0.3 V
T
J
Maximum operating junction temperature range –40 to 150 °C
T
stg
Storage temperature range –40 to 150 °C
ESD Electrostatic discharge, IEC ESD OUTL, OUTR ±8 kV
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
DISSIPATION RATINGS
POWER RATING
(1)
POWER RATING
(1)
PACKAGE R
θJC
(°C/W) R
θJA
(°C/W)
AT T
A
25°C AT T
A
70°C
TSSOP-14 (PW) 35 115
(2)
870 mW 348 mW
(1) Power rating is determined with a junction temperature of 125°C. This is the point where performance starts to degrade and long-term
reliability starts to be reduced. Thermal management of the final PCB should strive to keep the junction temperature at or below 125°C
for best performance and reliability.
(2) These data were taken with the JEDEC high-K test printed circuit board (PCB). For the JEDEC low-K test PCB, the R
θJA
is 185°C/W.
RECOMMENDED OPERATING CONDITIONS
MIN NOM MAX UNIT
V
DD
Supply voltage DC supply voltage 3 3.3 5.5 V
V
IH
High-level input voltage EN 60 % of V
DD
V
IL
Low-level input voltage EN 40 % of V
DD
T
A
Operating free-air temperature 0 70 °C
2 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): DRV603