Datasheet
www.ti.com
200
150
100
50
0
-50
-100
-150
-200
OutputV
oltage(mV)
0
Time(sec)
1m 2m 3m 4m 5m
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
OutputVoltageSpectrum(dBV)
20 100 1k
Frequency(Hz)
10k 20k
4.8 Pop/Click (Disable)
200
150
100
50
0
-50
-100
-150
-200
OutputVoltage(mV)
0
Time(sec)
1m 2m 3m 4m 5m
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
OutputVoltageSpectrum(dB
V)
20 100 1k
Frequency(Hz)
10k 20k
5 Related Documentation from Texas Instruments
Related Documentation from Texas Instruments
Figure 14. Pop/Click (Enable)
The DRV600 shows very low pop interference during the enable time; only two small, high-frequency
spikes can be seen.
No input signal is applied. The measurement results are presented both in a time domain and in a
frequency domain.
The resistive load is 600 Ω in both examples.
Figure 15. Pop/Click (Disable)
During power-down, the click is even lower than during power-on (enable). A very small click is seen.
Table 7 contains a list of documents that have a detailed description of the integrated circuits used in the
design of the DRV600EVM. The data sheet can be obtained through the TI website .
Table 7. Related Documentation from Texas Instruments
PART NUMBER LITERATURE NUMBER
DRV600 SLOS536
SLOU205 – July 2007 DRV600EVM User's Guide 11
Submit Documentation Feedback