Datasheet
9.0 Electrical Specifications (Continued)
70 www.national.com
9.4.5 100BASE-TX Transmit Timing
Note: Normal Mismatch is the difference between the maximum and minimum of all rise and fall times.
Note: Rise and fall times taken at 10% and 90% of the +1 or -1 amplitude.
Parameter Description Notes Min Typ Max Units
T4.5.1 100 Mb/s TPTD+/− Rise and
Fall Times
see Test Conditions section 3 4 5 ns
100 Mb/s Rise/Fall Mismatch 500 ps
T4.5.2 100 Mb/s TPTD+/−
Transmit Jitter
1.4 ns
TPTD+/-
T4.5.1
T4.5.1
T4.5.1
T4.5.1
+1 RISE +1 FALL
-1 FALL
-1 RISE
TPTD+/-
EYE PATTERN
T4.5.2
T4.5.2