Datasheet

DP83630
www.ti.com
SNLS335B OCTOBER 2010REVISED APRIL 2013
10.1.12 MII Interrupt Status and Event Control Register (MISR)
This register contains event status and enables for the interrupt function. If an event has occurred since
the last read of this register, the corresponding status bit will be set. If the corresponding enable bit in the
register is set, an interrupt will be generated if the event occurs. The MICR register controls must also be
set to allow interrupts. The status indications in this register will be set even if the interrupt is not enabled.
Table 10-14. MII Interrupt Status and Event Control Register (MISR), address 0x12
Bit Bit Name Default Description
15 LQ_INT 0, RO/COR Link Quality Interrupt:
1 = Link Quality interrupt is pending and is cleared by the current read.
0 = No Link Quality interrupt pending.
14 ED_INT 0, RO/COR Energy Detect Interrupt:
1 = Energy detect interrupt is pending and is cleared by the current read.
0 = No energy detect interrupt pending.
13 LINK_INT 0, RO/COR Change of Link Status Interrupt:
1 = Change of link status interrupt is pending and is cleared by the current read.
0 = No change of link status interrupt pending.
12 SPD_INT 0, RO/COR Change of Speed Status Interrupt:
or Change of speed status interrupt. This function is selected if MICR[3] is set to 0.
SPD_DUP_INT 1 = Speed status change interrupt is pending and is cleared by the current read.
0 = No speed status change interrupt pending.
Change of Speed/Duplex Interrupt:
Change of speed or duplex status interrupt. This function is selected if MICR[3] is
set to 1.
1 = Speed/duplex status change interrupt is pending and is cleared by the current
read.
0 = No speed/duplex status change interrupt pending.
11 DUP_INT 0, RO/COR Change of Duplex Status Interrupt:
or Change of duplex status interrupt. This function is selected if MICR[3] is set to 0.
PTP_INT 1 = Duplex status change interrupt is pending and is cleared by the current read.
0 = No duplex status change interrupt pending.
PTP Interrupt:
PTP interrupt. This function is selected if MICR[3] is set to 1. PTP interrupt status
should be read from the PTP_STS register. This interrupt will not be rearmed until
the PTP_STS register indicates no further PTP status is available.
1 = PTP interrupt is pending and is cleared by the current read.
0 = No PTP interrupt pending.
10 ANC_INT 0, RO/COR Auto-Negotiation Complete Interrupt:
1 = Auto-negotiation complete interrupt is pending and is cleared by the current
read.
0 = No Auto-negotiation complete interrupt pending.
9 FHF_INT 0, RO/COR False Carrier Counter Half-Full Interrupt:
or False carrier counter half-full interrupt. This function is selected if the PHYCR2[8:7]
CTR_INT are both 0.
1 = False carrier counter half-full interrupt is pending and is cleared by the current
read.
0 = No false carrier counter half-full interrupt pending.
CTR Interrupt:
False carrier or Receive Error counter half-full interrupt. This function is selected if
either of PHYCR2[8:7] are set.
1 = False carrier or receive error counter half-full interrupt is pending and is cleared
by the current read.
0 = No false carrier or receive error counter half-full interrupt pending.
Copyright © 2010–2013, Texas Instruments Incorporated Register Block 89
Submit Documentation Feedback
Product Folder Links: DP83630