Datasheet
Creating Pattern Sequences
www.ti.com
Figure 2-36. DLP LightCrafter GUI Sequence Settings Tab in Stored Pattern Sequence Tab
3. Set Pattern settings by updating the following parameters inside the Pattern Setting box:
• Bit Depth: bit depth of the image. Allowed values are from 1 to 8.
• Pattern Count: amount of patterns to display in sequence. Allowed values 1 to 96 divided by the bit
depth. For example, if the bit depth is 8, the maximum amount of patterns is 96 / 8 = 12. If the bit
depth is 1, the maximum amount of patterns is 96/1 = 96.
• Pattern Type
– Normal: display the pattern sequence. Available for all bit depths.
– Inverted: display the pattern sequence with each pattern followed by its inverted pattern.
Available for pattern sequences with Bit Depth equal to 1.
– HW Pattern: display a pattern sequence created from hardwired (HW) patterns. See
Section 2.8.1.1 for more details.
• Trigger Type: selects how the patterns are triggered.
– Auto: patterns displayed after end of Trigger Period.
– Command: patterns displayed when the Next button is pressed.
– External (Positive): patterns displayed after an external active high trigger signal.
– External (Negative):patterns display after an external active low trigger signal.
• LED Select: selects which color LED is active (Red, Green, or Blue). See Section 2.8.1.2 for
details about using the "Multiple" setting.
• Trigger Delay: number of microseconds delay after trigger is received and pattern is displayed.
See Figure 2-37.
• Exposure Time: number of microseconds the pattern is displayed. Input 0 to display the pattern
through the whole trigger period. See Figure 2-37.
• Trigger Period: number of microseconds delay between two consecutive patterns. See Figure 2-
37.
36
Operating the DLP LightCrafter DLPU006C–January 2012–Revised December 2013
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated