Datasheet
Register 88: LCD Controller Software Reset (SRLCD), offset 0x590
The SRLCD register provides software the capability to reset the available LCD module.
A peripheral is reset by software using a simple two-step process:
1. Software sets a bit (or bits) in the SRLCD register. While the SRLCD bit is 1, the peripheral is
held in reset.
2. Software completes the reset process by clearing the SRLCD bit.
There may be latency from the clearing of the SRLCD bit to when the peripheral is ready for use.
Software should check the corresponding PRLCD bit to verify that the LCD Module registers are
ready to be accessed.
Important: This register should be used to reset the LCD controller modules.
LCD Controller Software Reset (SRLCD)
Base 0x400F.E000
Offset 0x590
Type RW, reset 0x0000.0000
16171819202122232425262728293031
reserved
ROROROROROROROROROROROROROROROROType
0000000000000000Reset
0123456789101112131415
R0reserved
RWROROROROROROROROROROROROROROROType
0000000000000000Reset
DescriptionResetTypeNameBit/Field
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0ROreserved31:1
LCD Module 0 Software Reset
DescriptionValue
LCD module 0 is not reset.0
LCD module 0 is reset.1
0RWR00
December 13, 2013392
Texas Instruments-Advance Information
System Control