Datasheet
""#
SBAS255C − JUNE 2004 − REVISED APRIL 2009
www.ti.com
23
RETRIEVAL BEFORE CONV TOGGLES
(CONTINUOUS MODE)
Data retrieval before CONV toggles is the most
straightforward method. Data retrieval begins soon after
DVALID
goes low and finishes before CONV toggles; as
shown in Figure 23. For best performance, data retrieval
must stop t
28
before CONV toggles. This method is most
appropriate for longer integration times. The maximum
time available for readback is T
INT
– t
27
– t
28
. For DCLK =
10MHz and CLK = 4MHz, the maximum number of
DDC114s that can be daisy-chained together (FORMAT =
high) is calculated by Equation 1:
T
INT
* 355.125ms
80t
DCLK
NOTE: 64τ
DCLK
is used for FORMAT = low.
where τ
DCLK
is the period of the data clock. For example,
if T
INT
= 1000µs and DCLK = 10MHz, the maximum
number of DDC114s (FORMAT = high) is shown in
Equation 2:
1000ms * 355.125ms
(
80
)(
100ns
)
+ 80.60 ³ 80 DDC114s
(or 100 for FORMAT = low).
SYMBOL
DESCRIPTION
CLK = 4MHz, CLK_4X = 0 CLK = 4.8MHz, CLK_4X = 0
UNITS
SYMBOL DESCRIPTION
MIN TYP MAX MIN TYP MAX
UNITS
t
27
Cont Mode Data Ready 345.00 ± 0.125 287.5 ± 0.104 µs
t
28
Data Retrieval Shutdown Before Edge of CONV 10 10 µs
Figure 23. Readback Before CONV Toggles
(1)
(2)
……
……
Side B
Data
Side A
Data
T
INT
T
INT
t
27
t
28
CONV
DVALID
DCLK
DOUT