Datasheet

DDC112
23
SBAS085B
www.ti.com
CLK = 10MHz CLK = 15MHz
SYMBOL DESCRIPTION MIN TYP MAX MIN TYP MAX UNITS
t
27
Cont Mode Data Ready 421.2 280.8 µs
t
28
Data Retrieval Shutdown Before Edge of CONV 10 10 µs
••••••
••••••
Side B
Data
Side A
Data
T
INT
T
INT
t
27
t
28
CONV
DVALID
DXMIT
DCLK
DOUT
FIGURE 24. Readback
Before
CONV Toggles.
T
INT
t
27
t
29
t
26
T
INT
T
INT
••• ••• •••
••• ••• •••
Side A
Data
Side B
Data
Side A
Data
CONV
DVALID
DXMIT
DCLK
DOUT
FIGURE 25. Readback
After
CONV Toggles.
CLK = 10MHz CLK = 15MHz
SYMBOL DESCRIPTION MIN TYP MAX MIN TYP MAX UNITS
t
26
Hold Time for DXMIT HIGH Before Falling Edge 2 1.33 µs
of DVALID
t
27
Cont Mode Data Ready 421.2 280.8 µs
t
29
Data Retrieval Start-Up After Edge of CONV 10 10 µs