Datasheet
www.ti.com
EVM Performance
Figure 6. Layer 4, Bottom Signal Plane
Figure 7. Bottom Silkscreen
3 EVM Performance
The DAC9881 is optimized for DC performance; total harmonic distortion (THD) is typically at -80 dB. The
EVM INL and DNL testing is performed using a high-density DAC bench test board, an Agilent 3458A
digital multimeter, and a personal computer (PC) running LabVIEW™ software. The EVM board is tested
for all codes of 262,144 × 8 bits organization and the DAC is allowed to settle for 1 ms before the meter is
read. This process is repeated for all codes to generate the measurements for INL and DNL.
Figure 8 shows the INL and DNL characteristic plots.
7
SLAU279A–March 2009–Revised November 2009 DAC9881 Evaluation Module
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated