Datasheet
SLAS353 − DECEMBER 2001
6
www.ti.com
t
su5
t
h5
t
w6
t
w7
t
s
V
OUT
V
OUT
RST
RSTSEL
+FS
(RSTSEL = Low)
+FS
−FS
−FS
(RSTSEL = High)
Min-Scale
Mid-Scale
Figure 2. Reset Timing
TYPICAL CHARACTERISTICS
This condition applies to all typical characteristics: V
REF
H = AV
DD
, V
REF
L = AGND, T
A
= 25°C (unless
otherwise noted)
−64
−48
−32
−16
0
16
32
48
64
Linearity Error − LSB
Digital Input Code
LINEARITY ERROR AND DIFFERENTIAL LINEARITY ERROR
vs
DIGITAL INPUT CODE
−2
−1.5
−1
−0.5
0
0.5
1
1.5
2
0 8192 16384 24576 32768 40960 49152 57344 65535
Differential Linearity Error − LSB
AV
DD
= 2.7 V, T
A
= 85°C
Figure 3