Datasheet

www.ti.com
PACKAGE/ORDERING INFORMATION
ABSOLUTE MAXIMUM RATINGS
DAC7821
SBAS365B OCTOBER 2005 REVISED JULY 2007
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be
more susceptible to damage because very small parametric changes could cause the device not to meet its published
specifications.
For the most current package and ordering information, see the Package Option Addendum at the end of this
document, or see the TI website at www.ti.com .
over operating free-air temperature range (unless otherwise noted)
(1)
DAC7821 UNIT
V
DD
to GND –0.3 to +7 V
Digital input voltage to GND –0.3 to V
DD
+ 0.3 V
V
(IOUT)
to GND –0.3 to V
DD
+ 0.3 V
Operating temperature range –40 to +125 ° C
Storage temperature range –65 to +150 ° C
Junction temperature (T
J
max) +150 ° C
ESD Rating, HBM 3000 V
ESD Rating, CDM 1000 V
(1) Stresses above those listed under absolute maximum ratings may cause permanent damage to the device. Exposure to absolute
maximum conditions for extended periods may affect device reliability.
2