Datasheet

Digitally Programmable Current Source Application
3-6
Table 35.Digitally Programmable Current Source Configuration
Jumper Setting
Reference
VOUTA VOUTD
Function
W25 12 12 VSS is tied to AGND
W1 12 N/A VOUTS1A is feedback to VOUTA
W20 N/A 12 VOUTS1D is feedback to VOUTD
W6 CLOSED N/A DAC A is configured for unipolar mode of operation
W9 N/A CLOSED DAC D is configured for unipolar mode of operation
W2 12 N/A DAC A is connected to J42
W10 N/A 12 DAC A is connected to J48
J4 12 78 DAC A or DAC D is connected to J52
J5 23 23 DAC A or DAC D is routed to the positive input of U2
TP9 CLOSED CLOSED Transistor, Q1, loop is closed
TP10 CLOSED CLOSED Transistor, Q2, loop is closed
Figure 32. Digitally Programmable Current Source
DAC Module
AGND
OFSR 1OFSR 2
DGND
V
OU T
V
CC
/V
SS
IOV
DD
V
OUT
S1
V
OUT
S2
TP1
125
+5 V
6.5-A Digital Current Meter
Q1
+5 V
+
+
Ohms
A