Datasheet
DAC3484
www.ti.com
SLAS749C –MARCH 2011–REVISED AUGUST 2012
Register name: config32 – Address: 0x20, Default: 0x2400
Register
Default
Address Bit Name Function
Value
Name
config32 0x20 15:12 syncsel_fifoin(3:0) Selects the syncing source(s) of the FIFO input side. A ‘1’ in the bit enables the 0010
signal as a sync source. More than one sync source is permitted.
MM Bit 15: sif_sync (via config31)
MM Bit 14: Always zero
MM Bit 13: FRAME
MM Bit 12: SYNC
11:8 syncsel_fifoout(3:0) Selects the syncing source(s) of the FIFO output side. A ‘1’ in the bit enables the 0100
signal as a sync source. More than one sync source is permitted.
MM Bit 11: sif_sync (via config31)
MM Bit 10: OSTR – Dual Sync Sources Mode
MM Bit 9: FRAME – Single Sync Source mode
MM Bit 8: SYNC – Single Sync Source mode
7:1 Reserved Reserved for factory use. 0000
0 clkdiv_sync_sel Selects the signal source for clock divider synchronization. 0
clkdiv_sync_sel Sync Source
0 OSTR
1 FRAME or SYNC, based on syncsel_fifoin source
selection (config32, bit<15:12>)
Register name: config33 – Address: 0x21, Default: 0x0000
Register
Default
Address Bit Name Function
Value
Name
config33 0x21 15:0 Reserved Reserved for factory use. 0x0000
Register name: config34 – Address: 0x22, Default: 0x1B1B
Register
Default
Address Bit Name Function
Value
Name
config34 0x22 15:14 pathA_in_sel(1:0) Selects the word used for the A channel path. 00
13:12 pathB_in_sel(1:0) Selects the word used for the B channel path. 01
11:10 pathC_in_sel(1:0) Selects the word used for the C channel path. 10
9:8 pathD_in_sel(1:0) Selects the word used for the D channel path. 11
7:6 DACA_out_sel(1:0) Selects the word used for the DACA output. 00
5:4 DACB_out_sel(1:0) Selects the word used for the DACB output. 01
3:2 DACC_out_sel(1:0) Selects the word used for the DACC output. 10
1:0 DACD_out_sel(1:0) Selects the word used for the DACD output. 11
Copyright © 2011–2012, Texas Instruments Incorporated Submit Documentation Feedback 43
Product Folder Links: DAC3484