A.C. and Timing Characteristics
Values shown in this table are design targets and are subject to change before product release.
The following specifications apply for V
A
= +2.7V to +5.5V, V
REFIN
= V
A
, C
L
= 200 pF to GND, f
SCLK
= 30 MHz, input code
range 3 to 252. Boldface limits apply for T
MIN
≤ T
A
≤ T
MAX
and all other limits are at T
A
= 25°C, unless otherwise specified.
Units
Symbol Parameter Conductions Typical
(1)
Limits
(1)
(Limits)
f
SCLK
SCLK Frequency 40 30 MHz (max)
40h to C0h code change
t
s
Output Voltage Settling Time
(2)
3 4.5 µs (max)
R
L
= 2 kΩ, C
L
= 200 pF
SR Output Slew Rate 1 V/µs
Glitch Impulse Code change from 80h to 7Fh 12 nV-sec
Digital Feedthrough 0.5 nV-sec
Digital Crosstalk 1 nV-sec
DAC-to-DAC Crosstalk 3 nV-sec
Multiplying Bandwidth V
REFIN
= 2.5V ± 0.1Vpp 160 kHz
V
REFIN
= 2.5V ± 1Vpp
Total Harmonic Distortion 70 dB
input frequency = 10kHz
V
A
= 3V 6 µsec
t
WU
Wake-Up Time
V
A
= 5V 39 µsec
1/f
SCLK
SCLK Cycle Time 25 33 ns (min)
t
CH
SCLK High time 7 10 ns (min)
t
CL
SCLK Low Time 7 10 ns (min)
SYNC Set-up Time prior to SCLK
t
SS
4 10 ns (min)
Falling Edge
Data Set-Up Time prior to SCLK Falling
t
DS
1.5 3.5 ns (min)
Edge
Data Hold Time after SCLK Falling
t
DH
1.5 3.5 ns (min)
Edge
t
CFSR
SCLK fall prior to rise of SYNC 0 3 ns (min)
t
SYNC
SYNC High Time 6 10 ns (min)
(1) Typical figures are at T
J
= 25°C, and represent most likely parametric norms. Test limits are specified to AOQL (Average Outgoing
Quality Level).
(2) This parameter is specified by design and/or characterization and is not tested in production.
6 Submit Documentation Feedback Copyright © 2006–2013, Texas Instruments Incorporated