Datasheet
CY54FCT573T, CY74FCT573T
8-BIT LATCHES
WITH 3-STATE OUTPUTS
SCCS068 – OCTOBER 2001
6
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
switching characteristics over operating free-air temperature range (see Figure 1)
PARAMETER
FROM TO
CY54FCT573AT
UNIT
PARAMETER
(INPUT) (OUTPUT)
MIN MAX
UNIT
t
PLH
D
O
1.5 5.6
ns
t
PHL
D
O
1.5 5.6
ns
t
PLH
LE
O
2 9.8
ns
t
PHL
LE
O
2 9.8
ns
t
PZH
OE
O
1.5 7.5
ns
t
PZL
OE
O
1.5 7.5
ns
t
PHZ
OE
O
1.5 6.5
ns
t
PLZ
OE
O
1.5 6.5
ns
switching characteristics over operating free-air temperature range (see Figure 1)
PARAMETER
FROM TO
CY74FCT573T CY74FCT573AT CY74FCT573CT
UNIT
PARAMETER
(INPUT) (OUTPUT)
MIN MAX MIN MAX MIN MAX
UNIT
t
PLH
D
O
1.5 8 1.5 5.2 1.5 4.7
ns
t
PHL
D
O
1.5 8 1.5 5.2 1.5 4.7
ns
t
PLH
LE
O
2 13 2 8.5 2 5.5
ns
t
PHL
LE
O
2 13 2 8.5 2 5.5
ns
t
PZH
OE
O
1.5 12 1.5 6.5 1.5 5.5
ns
t
PZL
OE
O
1.5 12 1.5 6.5 1.5 5.5
ns
t
PHZ
OE
O
1.5 7.5 1.5 5.5 1.5 5
ns
t
PLZ
OE
O
1.5 7.5 1.5 5.5 1.5 5
ns