Datasheet


  
  
SCCS041B SEPTEMBER 1994 REVISED SEPTEMBER 2001
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
recommended operating conditions (see Note 2)
MIN NOM MAX UNIT
V
CC
Supply voltage 4.75 5 5.25 V
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
I
OH
High-level output current 15 mA
I
OL
Low-level output current 12 mA
T
A
Operating free-air temperature 40 85 °C
NOTE 2: All unused inputs of the device must be held at V
CC