Maximum Ratings
[3, 4]
(Above which the useful life may be impaired. For user
guidelines, not tested.)
Storage Temperature .....................................55°C to +125°C
Ambient Temperature with
Power Applied..................................................55°C to +125°C
DC Input Voltage .................................................0.5V to +7.0V
DC Output Voltage ..............................................0.5V to +7.0V
DC Output Current
(Maximum Sink Current/Pin) ...........................60 to +120 mA
Power Dissipation..........................................................1.0W
Static Discharge Voltage............................................>2001V
(per MIL-STD-883, Method 3015)
Notes:
1. H = HIGH Voltage Level.
L = LOW Voltage Level.
X = Don’t Care.
Z = HIGH Impedance.
=LOW-to-HIGH transition.
2. Output level before indicated steady-state input conditions were established.
3. Operation beyond the limits set forth may impair the useful life of the device. Unless otherwise noted, these limits are over the operating free-air temperature range.
4. Unused inputs must always be connected to an appropriate logic voltage level, preferably either V
CC
or ground.
Pin Description
Name Description
D Data Inputs
CLK Clock Inputs
CLKEN Clock Enable Inputs (Active LOW)
CLR Asynchronous Clear Inputs (Active LOW)
OE Output Enable Inputs (Active LOW)
Q Three-State Outputs
Function Table
[1]
Inputs Outputs
OE CLR CLKEN CLK D Q Function
H X X X X Z High Z
L L X X X L Clear
L H H X X Q
[2]
Hold
H H L L Z Load
H H L H Z
L H L L L
L H L H H
Operating Range
Range
Ambient
Temperature V
CC
Industrial 40°C to +85°C 5V ± 10%