Datasheet
Device Operation (Continued)
Figure 5 shows the CLC001 with an AC-coupled, single
ended input connection. The 82.5Ω resister in parallel with
825Ω gives the equivalent termination resistance of 75Ω.
R
BB
set at 5kΩ provides 1.25V of DC bias to the input.
A typical DC-coupled, twisted pair cable connection is shown
in Figure 6. The CLC001 is driven differentially. The line is
terminated with a termination resistor equal to the imped-
ance of the line being driven. The actual resistor value is
media specific, but typically is between 100 and 120Ω de-
pending upon the cable. This resistor should be located
close to the CLC001 inputs pins to minimize the resulting
stub length between the resistor and device pads.
10132905
FIGURE 5. Single Ended 75Ω Coaxial Cable, AC-coupled
10132906
FIGURE 6. Twisted Pair Cable, DC-coupled
CLC001
www.national.com7