Device Operation (Continued)
A typical LVDS input connection is shown in Figure 9. The
media is driven differentially by an LVDS driver. The line is
terminated with a termination resistor equal to the imped-
ance of the line being driven. The actual resistor value is
media specific, but typically is between 100 and 120. This
resistor should be located close to the CLC001 inputs pins to
minimize the resulting stub length between the resistor and
device pads. The CLC001 supports
±
100mV thresholds
across the entire LVDS common mode range of 0.1V to 2.3V
for a 200mV differential signal.
10132909
FIGURE 9. LVDS, DC-coupled
CLC001
www.national.com9