Datasheet

6
Data Set-up Time t
SU
2 50 - 65 - 75 - ns
4.5 10 - 13 - 15 - ns
6 9 -11-13-ns
Data Hold Time t
H
2 3-3-3-ns
4.5 3 - 3 - 3 - ns
6 3-3-3-ns
STR Set-up Time t
SU
2 100 - 125 - 150 - ns
4.5 20 - 25 - 30 - ns
6 17 - 21 - 26 - ns
STR Hold Time t
H
2 0-0-0-ns
4.5 0 - 0 - 0 - ns
6 0-0-0-ns
Maximum CP Frequency f
CL (MAX)
2 6-5-4-MHz
4.5 30 - 24 - 20 - MHz
6 35 - 28 - 24 - MHz
HCT TYPES
CP Pulse Width t
W
4.5 16 - 20 - 24 - ns
STR Pulse Width t
WH
4.5 16 - 20 - 24 - ns
Data Set-up Time t
SU
4.5 10 - 13 - 15 - ns
Data Hold Time t
H
4.5 4 - 4 - 4 - ns
STR Set-up Time t
SU
4.5 20 - 25 - 30 - ns
STR Hold Time t
H
4.5 0 - 0 - 0 - ns
Maximum CP Frequency f
CL (MAX)
4.5 30 - 24 - 20 - MHz
Switching Specifications Input t
r
, t
f
= 6ns
PARAMETER SYMBOL
TEST
CONDITIONS
V
CC
(V)
25
o
C -40
o
C TO 85
o
C -55
o
C TO 125
o
C
UNITSMIN TYP MAX MIN MAX MIN MAX
HC TYPES
Propagation Delay Time
(Figure 1)
t
PLH,
t
PHL
C
L
= 50pF 2 - - 150 - 190 - 225 ns
CP to QS
1
4.5 - - 30 - 38 - 45 ns
C
L
=15pF 5 - 12 - - - - - ns
C
L
= 50pF 6 - - 26 - 33 - 38 ns
CP to QS
2
t
PLH,
t
PHL
C
L
= 50pF 2 - - 135 - 170 - 205 ns
4.5 - - 27 - 34 - 41 ns
C
L
=15pF 5 - 11 - - - - - ns
C
L
= 50pF 6 - - 23 - 29 - 35 ns
CP to Q
n
t
PLH,
t
PHL
C
L
= 50pF 2 - - 195 - 245 - 295 ns
4.5 - - 39 - 49 - 59 ns
5 - 16 - - - - - ns
6 - - 33 - 42 - 50 ns
STR to Q
n
t
PLH,
t
PHL
C
L
= 50pF 2 - - 180 - 225 - 270 ns
4.5 - - 36 - 45 - 54 ns
6 - - 31 - 38 - 46 ns
Prerequisite for Switching Specifications (Continued)
CHARACTERISTIC SYMBOL V
CC
(V)
25
o
C -40
o
C TO 85
o
C -55
o
C TO 125
o
C
UNITSMIN MAX MIN MAX MIN MAX
CD74HC4094, CD74HCT4094