Datasheet
5
Power Dissipation Capacitance
(Notes 3, 4)
C
PD
-5-65-----pF
HCT TYPES
Propagation Delay,
Input to Y (Figure 2)
t
PLH
, t
PHL
C
L
= 50pF 4.5 - - 35 - 44 - 53 ns
Any Input to Yt
PLH
, t
PHL
C
L
= 15pF 5 - 14 - - - - - ns
Output Transition Time
(Figure 2)
t
TLH
, t
THL
C
L
= 50pF 4.5 - - 15 - 19 - 22 ns
Input Capacitance C
IN
- - - - 10 - 10 - 10 pF
Power Dissipation Capacitance
(Notes 3, 4)
C
PD
-5-70-----pF
NOTES:
3. C
PD
is used to determine the dynamic power consumption, per package.
4. P
D
= V
CC
2
f
i
(C
PD
+ C
L
) where: f
i
= Input Frequency, C
L
= Output Load Capacitance, V
CC
= Supply Voltage.
Switching Speciļ¬cations Input t
r
, t
f
= 6ns (Continued)
PARAMETER SYMBOL
TEST
CONDITIONS V
CC
(V)
25
o
C
-40
o
C TO
85
o
C
-55
o
C TO
125
o
C
UNITSMIN TYP MAX MIN MAX MIN MAX
Test Circuits and Waveforms
FIGURE 1. HC AND HCU TRANSITION TIMES AND PROPAGA-
TION DELAY TIMES, COMBINATION LOGIC
FIGURE 2. HCT TRANSITION TIMES AND PROPAGATION
DELAY TIMES, COMBINATION LOGIC
t
PHL
t
PLH
t
THL
t
TLH
90%
50%
10%
50%
10%
INVERTING
OUTPUT
INPUT
GND
V
CC
t
r
= 6ns t
f
= 6ns
90%
t
PHL
t
PLH
t
THL
t
TLH
2.7V
1.3V
0.3V
1.3V
10%
INVERTING
OUTPUT
INPUT
GND
3V
t
r
= 6ns
t
f
= 6ns
90%
CD54HC42, CD74HC42, CD74HCT42