Datasheet

4
“ON” Resistance
I
O
= 1mA
(Figure 1)
R
ON
V
CC
V
CC
or
GND
4.5 - 25 80 - 106 - 128
6 - 20 75 - 94 - 113
9 - 15 60 - 78 - 95
V
CC
to
GND
4.5 - 35 95 - 118 - 142
6 - 24 84 - 105 - 126
9 - 16 70 - 88 - 105
“ON” Resistance
Between Any Two
Switches
R
ON
V
CC
-4.5-1-----
6 - 0.75 - ----
9-0.5-----
Quiescent Device
Current
I
CC
V
CC
or
GND
- 6 - - 2 - 20 - 40 µA
10 - - 16 - 160 - 320 µA
HCT TYPES
High Level Input
Voltage
V
IH
- - 4.5 to
5.5
2-- 2 - 2 - V
Low Level Input
Voltage
V
IL
- - 4.5 to
5.5
- - 0.8 - 0.8 - 0.8 V
Input Leakage
Current
(Any Control)
I
IL
V
CC
or
GND
- 5.5 - - ±0.1 - ±1-±1 µA
Off-Switch Leakage
Current
I
Z
V
IL
V
CC
or
GND
5.5 - - ±0.1 - ±1-±1 µA
“ON” Resistance
I
O
= 1mA
(Figure 1)
R
ON
V
CC
V
CC
or
GND
4.5 - 25 80 - 106 - 128
V
CC
to
GND
4.5 - 35 95 - 118 - 142
“ON” Resistance
Between Any Two
Switches
R
ON
V
CC
-4.5-1-----
Quiescent Device
Current
I
CC
V
CC
or
GND
- 5.5 - - 2 - 20 - 40 µA
Additional Quiescent
Device Current Per
Input Pin: 1 Unit Load
I
CC
(Note 3)
V
CC
- 2.1
- 4.5 to
5.5
- 100 360 - 450 - 490 µA
NOTE:
3. For dual-supply systems theoretical worst case (V
I
= 2.4V, V
CC
= 5.5V) specification is 1.8mA.
DC Electrical Specifications (Continued)
PARAMETER SYMBOL
TEST
CONDITIONS
V
CC
(V)
25
o
C -40
o
C TO 85
o
C -55
o
C TO 125
o
C
UNITSV
I
(V) V
IS
(V) MIN TYP MAX MIN MAX MIN MAX
HCT Input Loading Table
INPUT UNIT LOADS
All 1
NOTE: Unit Load is I
CC
limit specified in DC Electrical Specifica-
tions table, e.g., 360µA max at 25
o
C.
CD54HC4066, CD74HC4066, CD74HCT4066