Datasheet

7
CPD to Q
n
t
PLH
, t
PHL
C
L
= 50pF 2 - - 220 - 270 - 325 ns
C
L
= 50pF 4.5 - - 43 - 54 - 65 ns
C
L
= 15pF 5 - 18 - - - - ns
C
L
= 50pF 6 - - 37 - 46 - 55 ns
PL to Q
n
t
PLH
, t
PHL
C
L
= 50pF 2 - - 220 - 275 - 330 ns
C
L
= 50pF 4.5 - - 44 - 55 - 66 ns
C
L
= 15pF 5 - 18 - ----ns
C
L
= 50pF 6 - - 37 - 47 - 56 ns
MR to Q
n
t
PHL
C
L
= 50pF 2 - - 200 - 250 - 300 ns
C
L
= 50pF 4.5 - - 40 - 50 - 60 ns
C
L
= 15pF 5 - 17 - ----ns
C
L
= 50pF 6 - - 34 - 43 - 51 ns
Transition Time t
TLH
, t
THL
C
L
= 50pF 2 - - 75 - 95 - 110 ns
Q, TCU, TCD 4.5 - - 15 - 19 - 22 ns
6 - - 13 - 16 - 19 ns
Input Capacitance C
IN
C
L
= 50pF - - - 10 - 10 - 10 pF
Power Dissipation Capacitance
(Notes 3, 4)
C
PD
C
L
= 15pF 5 - 40 - ----pF
HCT TYPES
Propagation Delay t
PLH
, t
PHL
C
L
= 50pF 4.5 - - 27 - 34 - 41 ns
CPU to TCU C
L
= 15pF 5 - 11 - ----ns
CPU to TCD t
PLH
, t
PHL
C
L
= 50pF 4.5 - - 27 - 34 - 41 ns
C
L
= 15pF 5 - 11 - ----ns
CPU to Q
n
t
PLH
, t
PHL
C
L
= 50pF 4.5 - - 40 - 50 - 60 ns
C
L
= 15pF 5 - 17 - ----ns
CPD to Q
n
t
PLH
, t
PHL
C
L
= 50pF 4.5 - - 40 - 50 - 60 ns
C
L
= 15pF 5 - 17 - ----ns
PL to Q
n
t
PLH
, t
PHL
C
L
= 50pF 4.5 - - 46 - 58 - 69 ns
C
L
= 15pF 5 - 21 - ----ns
MR to Q
n
t
PHL
C
L
= 50pF 4.5 - - 43 - 54 - 65 ns
C
L
= 15pF 5 - 18 - ----ns
Transition Time t
TLH
, t
THL
C
L
= 50pF
Q, TCU, TCD 4.5 - - 15 - 19 - 22 ns
Input Capacitance C
IN
C
L
= 50pF - - - 10 - 10 - 10 pF
Power Dissipation Capacitance
(Notes 3, 4)
C
PD
C
L
= 15pF 5 - 50 - ----pF
NOTES:
3. C
PD
is used to determine the dynamic power consumption, per gate.
4. P
D
= V
CC
2
f
i
+ (C
L
V
CC
2
) where f
i
= Input Frequency, C
L
= Output Load Capacitance, V
CC
= Supply Voltage.
Switching Specifications Input t
r
, t
f
= 6ns (Continued)
PARAMETER SYMBOL
TEST
CONDITIONS
V
CC
(V)
25
o
C -40
o
C TO 85
o
C -55
o
C TO 125
o
C
UNITSMIN TYP MAX MIN MAX MIN MAX
CD54/74HC192, CD54/74HC193, CD54/74HCT193