Datasheet
5
PL Pulse Width t
WL
2 80 - 100 - 120 - ns
4.5 16 - 20 - 24 - ns
614-17-20-ns
Set-up Time t
SU
2 80 - 100 - 120 - ns
DS to CP 4.5 16 - 20 - 24 - ns
614-17-20-ns
CE to CP t
SU(L)
2 80 - 100 - 120 - ns
4.5 16 - 20 - 24 - ns
614-17-20-ns
D0-D7 to PL t
SU
2 80 - 100 - 120 - ns
4.5 16 - 20 - 24 - ns
614-17-20-ns
Hold Time t
H
235-45-55-ns
DS to CP or CE 4.5 7 - 9 - 11 - ns
66-8-9-ns
CE to CP t
H
20-0-0-ns
4.50-0-0-ns
60-0-0-ns
Recovery Time t
REC
2 100 - 125 - 150 - ns
PL to CP 4.5 20 - 25 - 30 - ns
617-21-26-ns
Maximum Clock Pulse
Frequency
f
MAX
26-5-4-MHz
4.5 30 - 24 - 20 - MHz
6 35 - 28 - 24 - MHz
HCT TYPES
CP Pulse Width t
WL
, t
WH
4.5 18 - 23 - 27 - ns
PL Pulse Width t
WL
4.5 20 - 25 - 30 - ns
Set-up Time
DS to CP
t
SU
4.5 20 - 25 - 30 - ns
CE to CP t
SU(L)
4.5 20 - 25 - 30 - ns
D0-D7 to PL t
SU
620-25-30-ns
Hold Time
DS to CP or CE
t
H
4.5 7 - 9 - 11 - ns
CE to CP t
S
,t
H
4.50-0-0-ns
Recovery Time
PL to CP
t
REC
4.5 20 - 25 - 30 - ns
Maximum Clock Pulse
Frequency
f
MAX
4.5 27 - 22 - 18 - MHz
Prerequisite For Switching Speciļ¬cations (Continued)
PARAMETER SYMBOL V
CC
(V)
25
o
C -40
o
C TO 85
o
C -55
o
C TO 125
o
C
UNITSMIN MAX MIN MAX MIN MAX
CD54HC165, CD74HC165, CD54HCT165, CD74HCT165