Datasheet

5
I to Y t
PLH,
t
PHL
C
L
= 50pF 2 - - 145 - 180 - 220 ns
4.5 - - 29 - 36 - 44 ns
C
L
=15pF 5 - 12 - - - - - ns
C
L
= 50pF 6 - - 25 - 31 - 38 ns
E to Y t
PLH,
t
PHL
C
L
= 50pF 2 - 120 - 150 - 180 ns
4.5 - 24 - 30 - 36 ns
C
L
=15pF 5 - 9 - - - - - ns
C
L
= 50pF 6 - - 20 - 26 - 31 ns
Output Transition Time
(Figure 1)
t
TLH
,t
THL
C
L
= 50pF 2 - - 75 - 95 - 110 ns
4.5 - - 15 - 19 - 22 ns
6 - - 13 - 16 - 19 ns
Input Capacitance C
IN
- - - - 10 - 10 - 10 pF
Power Dissipation Capacitance
(Notes 3, 4)
C
PD
-5-45-----pF
HCT TYPES
Propagation Delay (Figure 2) t
PLH
,
t
PHL
S to Y C
L
= 50pF 4.5 - - 34 - 43 - 51 ns
C
L
=15pF 5 - 14 - - - - ns
I to Y t
PLH
,
t
PHL
C
L
= 50pF 4.5 - - 24 - 30 - 36 ns
C
L
=15pF 5 - 9 - - - - - ns
I to Y t
PLH
,
t
PHL
C
L
= 50pF 4.5 - 34 - 43 - 51 ns
C
L
=15pF 5 - 14 - - - - - ns
E to Y t
PLH
,
t
PHL
C
L
= 50pF 4.5 - - 27 - 34 - 41 ns
C
L
=15pF 5 - 11 - - - - ns
Output Transition Time t
TLH
,t
THL
C
L
= 50pF 4.5 - - 15 - 19 - 22 ns
Input Capacitance C
IN
- - - - 10 - 10 - 10 pF
Power Dissipation Capacitance
(Notes 3, 4)
C
PD
-5-45-----pF
NOTES:
3. C
PD
is used to determine the dynamic power consumption, per multiplexer.
4. P
D
= V
CC
2
f
i
(C
PD
+ C
L
) where f
i
= Input Frequency, C
L
= Output Load Capacitance, V
CC
= Supply Voltage.
Switching Specifications Input t
r
, t
f
= 6ns (Continued)
PARAMETER SYMBOL
TEST
CONDITIONS
V
CC
(V)
25
o
C
-40
o
C TO
85
o
C
-55
o
C TO
125
o
C
UNITSMIN TYP MAX MIN MAX MIN MAX
Test Circuit and Waveform
FIGURE 1. PROPAGATION DELAY TIMES
t
r
= 6ns
E
I OR S
OUTPUT Y
t
PLH
t
f
= 6ns
90%
V
S
10%
V
S
t
PHL
CD54HC153, CD74HC153, CD54HCT153, CD74HCT153