Datasheet


     
SCHS340B − MARCH 2003 - REVISED JUNE 2003
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V ± 0.5 V, C
L
= 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
−55°C to
125°C
−40°C to
85°C
UNIT
PARAMETER
(INPUT)
(OUTPUT)
MIN MAX MIN MAX
UNIT
t
PLH
A or B
Any Y
2.4 9.5 2.5 8.6
ns
t
PHL
A or B Any Y
2.4 9.5 2.5 8.6
ns
t
PLH
A/B
Any Y
3.6 14.5 3.8 13.2
ns
t
PHL
A/B
Any Y
3.6 14.5 3.8 13.2
ns
t
PLH
G
Any Y
3.4 13.5 3.6 12.3
ns
t
PHL
G
Any Y
3.4 13.5 3.6 12.3
ns
operating characteristics, V
CC
= 5 V, T
A
= 25°C
PARAMETER TYP UNIT
C
pd