Datasheet

CD54ACT153, CD74ACT153
DUAL 4-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS
SCHS339 MARCH 2003
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER TEST CONDITIONS V
CC
T
A
= 25°C
55°C to
125°C
40°C to
85°C
UNIT
CC
MIN MAX MIN MAX MIN MAX
I
OH
= 50 µA 4.5 V 4.4 4.4 4.4
V
OH
I
OH
= 24 mA 4.5 V 3.94 3.7 3.8
V
V
OH
I
=
IH
IL
I
OH
= 50 mA
5.5 V 3.85
V
I
OH
= 75 mA
5.5 V 3.85
I
OL
= 50 µA 4.5 V 0.1 0.1 0.1
V
OL
I
OL
= 24 mA 4.5 V 0.36 0.5 0.44
V
V
OL
I
=
IH
IL
I
OL
= 50 mA
5.5 V 1.65
V
I
OL
= 75 mA
5.5 V 1.65
I
I
V
I
= V
CC
or GND 5.5 V ±0.1 ±1 ±1 µA
I
CC
V
I
= V
CC
or GND, I
O
= 0 5.5 V 8 160 80 µA
I
CC
V
I
= V
CC
2.1 V 4.5 V to 5.5 V 2.4 3 2.8 mA
C
i
10 10 10 pF
Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize
power dissipation. Test verifies a minimum 50- transmission-line drive capability at 85°C and 75- transmission-line drive capability at 125°C.
Additional quiescent supply current per input pin, TTL inputs high, 1 unit load
ACT INPUT LOAD TABLE
INPUT
UNIT LOAD
A or B 1
C 1
G
0.47
Unit Load is I
CC
limit specified in
electrical characteristics table
(e.g., 2.4 mA at 25°C).
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V ± 0.5 V, C
L
= 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
55°C to
125°C
40°C to
85°C
UNIT
(INPUT)
(OUTPUT)
MIN MAX MIN MAX
t
PLH
AorB
Y
5.5 22 5.7 20
ns
t
PHL
A
or
B
Y
5.5 22 5.7 20
ns
t
PLH
Any C
Y
4.5 18 4.6 16.4
ns
t
PHL
Any
C
Y
4.5 18 4.6 16.4
ns
t
PLH
G
Y
3.2 12.6 3.2 11.5
ns
t
PHL
G
Y
3.2 12.6 3.2 11.5
ns
operating characteristics, T
A
= 25°C
PARAMETER TYP UNIT
C
pd
Power dissipation capacitance 93 pF