Datasheet

CD74AC86
QUADRUPLE 2-INPUT EXCLUSIVE-OR GATE
SCHS324 JANUARY 2003
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range,
V
CC
= 1.5 V, C
L
= 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
55°C to
125°C
40°C TO
85°C
UNIT
(INPUT)
(OUTPUT)
MIN MAX MIN MAX
t
PLH
AorB
Y
135 123
ns
t
PHL
A
or
B
Y
135 123
ns
switching characteristics over recommended operating free-air temperature range,
V
CC
= 3 V ± 0.3 V, C
L
= 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
55°C to
125°C
40°C TO
85°C
UNIT
(INPUT)
(OUTPUT)
MIN MAX MIN MAX
t
PLH
AorB
Y
3.8 15.1 3.9 13.7
ns
t
PHL
A
or
B
Y
3.8 15.1 3.9 13.7
ns
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V ± 0.5 V, C
L
= 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
55°C to
125°C
40°C TO
85°C
UNIT
(INPUT)
(OUTPUT)
MIN MAX MIN MAX
t
PLH
AorB
Y
2.7 10.8 2.8 9.8
ns
t
PHL
A
or
B
Y
2.7 10.8 2.8 9.8
ns
operating characteristics, T
A
= 25°C
PARAMETER TYP UNIT
C
pd
Power dissipation capacitance 57 pF