Datasheet
5
Prerequisite For Switching Function
PARAMETER SYMBOL V
CC
(V)
-40
o
C TO 85
o
C -55
o
C TO 125
o
C
UNITSMIN MAX MIN MAX
AC TYPES
Data to CP Set-Up Time t
SU
1.5 2 - 2 - ns
3.3
(Note 9)
2-2-ns
5
(Note 10)
2-2-ns
Hold Time t
H
1.5 2 - 2 - ns
3.3 2 - 2 - ns
52-2-ns
Removal Time, MR to CP t
REM
1.5 2 - 2 - ns
3.3 2 - 2 - ns
52-2-ns
MR Pulse Width t
W
1.5 55 - 63 - ns
3.3 6.1 - 7 - ns
5 4.4 - 5 - ns
CP Pulse Width t
W
1.5 55 - 63 - ns
3.3 6.1 - 7 - ns
5 4.4 - 5 - ns
CP Frequency f
MAX
1.5 9 - 8 - MHz
3.3 81 - 71 - MHz
5 114 - 100 - MHz
ACT TYPES
Data to CP Set-Up Time t
SU
5
(Note 10)
2-2-ns
Hold Time t
H
52-2-ns
Removal Time MR to CP t
REM
52-2-ns
MR Pulse Width t
W
5 4.4 - 5 - ns
CP Pulse Width t
W
5 5.3 - 6 - ns
CP Frequency f
MAX
5 97 - 85 - MHz
Switching Speciļ¬cations Input t
r
, t
f
= 3ns, C
L
= 50pF (Worst Case)
PARAMETER SYMBOL V
CC
(V)
-40
o
C TO 85
o
C -55
o
C TO 125
o
C
UNITSMIN TYP MAX MIN TYP MAX
AC TYPES
Propagation Delay,
CP to Qn
t
PLH
, t
PHL
1.5 - - 154 - - 169 ns
3.3
(Note 9)
4.9 - 17.2 4.7 - 18.9 ns
5
(Note 10)
3.5 - 12.3 3.4 - 13.5 ns
CD54AC273, CD74AC273, CD54ACT273, CD74ACT273