Datasheet

CD54AC153, CD74AC153
DUAL 4-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS
SCHS334A – MARCH 2003 - REVISED MAY 2003
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range,
V
CC
= 3.3 V ± 0.3 V, C
L
= 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
–55°C to
125°C
–40°C to
85°C
UNIT
(INPUT)
(OUTPUT)
MIN MAX MIN MAX
t
PLH
AorB
Y
7 28 7.2 25.5
ns
t
PHL
A
or
B
Y
7 28 7.2 25.5
ns
t
PLH
Any C
Y
4.7 18.6 4.8 16.9
ns
t
PHL
Any
C
Y
4.7 18.6 4.8 16.9
ns
t
PLH
G
Y
4.1 16.5 4.3 15
ns
t
PHL
G
Y
4.1 16.5 4.3 15
ns
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V ± 0.5 V, C
L
= 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
–55°C to
125°C
–40°C to
85°C
UNIT
(INPUT)
(OUTPUT)
MIN MAX MIN MAX
t
PLH
AorB
Y
5 20 5.2 18.2
ns
t
PHL
A
or
B
Y
5 20 5.2 18.2
ns
t
PLH
Any C
Y
3.3 13.3 3.4 12.1
ns
t
PHL
Any
C
Y
3.3 13.3 3.4 12.1
ns
t
PLH
G
Y
3 11.8 3.1 10.7
ns
t
PHL
G
Y
3 11.8 3.1 10.7
ns
operating characteristics, T
A
= 25°C
PARAMETER TYP UNIT
C
pd